Sale!

Braun IV tubing part# 354212 w/ 2 CARESITE Needle-Free Injection case of 24

Original price was: $195.Current price is: $125.

Categories: , Brand:
No Sales Tax
1 year warranty on equipment orders
Commercial financing available for orders over $2,000
Braun IV tubing ref 354212
 
Case of 24 
 

15 drops/mL, Priming volume: 27 mL, Length: 129 in.

(15 drops/mL) Universal spike, slide clamp, pressure limited check valve, CARESITE injection sites 103 in. and 6 in. above distal end, free-flow protector clip, roller clamp, slide clamp and SPIN-LOCK® connector. Priming volume: 27 mL, Length: 129 in. (328 c

Specifications

Product Identification
Product Code 354212
WSN Number 08021-3542-12
Reference Number 354212
Safety Data
BPA Information Contains BPA
DEHP Information Contains DEHP
Latex Information Not Made With Natural Rubber
PVC Information Contains PVC
Storage and Shipping
Total Shelf Life (Months) 036
Ordering Unit Case
Units per Case 24
Dimensions per Case 13.450 x 11.200 x 8.390 inches
Shipping Weight per Case 4.519 lb
Sterility
Sterile Yes

Alaris Infusion Pump Specifications

Dimensions

  • Height: 8.8 In (22.4 cm)
  • Width: 6.9 In (17.5 cm)
  • Depth: 9 In (22.9 cm)
  • Weight: 7.2 lb (3.2 kg)

Battery

  • Battery run time is a function of the number of modules attached and module activity. With a new, fully charged battery, the system operates as follows before a “BATTERY DISCHARGED” message occurs:
  • 6 Hours: with one Pump module infusing at 25 mL/h
  • 6 Hours: with one Pump module infusing at 25 mL/h and one Auto-ID module
  • 3 Hours: with four Pump modules infusing at 25 mL/h
  • 3 Hours: with four Pump modules infusing at 25 mL/h and one Auto-ID module
  • 4.5 Hours: with one active SpO2 module
  • 6 Hours: with one Syringe module or PCA module infusing at 5 mL/h
  • 3 Hours: with four Syringe modules, or one PCA module and three Syringe modules, infusing at 5 mL/h
  • 4 Hours: with one active EtCO2 module

Communication Data Port

  • RS-232 with an RJ45 connector

Memory

  • The System configuration/data set is stored in compact flash memory along with operating software.
  • The events and error logs are stored in the onboard flash memory in the Alaris PC unit and modules. This is a nonvolatile memory and can be held indefinitely or until replaced with new data and not lost when power is turned off or the battery is in a weak/discharged state.
  • Module-specific parameters are stored for 8 hours when the system is turned off. After 8 hours of continuous off-time, or if a module is detached, module-specific trend data (if applicable) and module-specific operating parameters are automatically purged. If a PCA, SpO2, or EtCO2 module is detached and replaced with another PCA, SpO2, or EtCO2 module, its module-specific trend data is purged.
  • Memory will not be lost due to a weak/discharged battery as data is stored on flash memory as noted.
  • Compact flash memory: Stores application software, audio wave files, DataSet, and hex files data for operating system software, all needed to operate the Alaris PC Unit System.
  • On-board flash memory: Contains software needed to initially turn on the Alaris 8105 System. Stores boot software applications, and events, errors, and battery logs.

IV Safety

  • Guardrails Suite MX software is the most comprehensive safety software available
  • The wirelessly enabled software is available on every device
  • Provides the right protection for every infusion by double-checking dose and duration, as well as delivery rate, protecting critical infusions like chemotherapy

Analytics

  • Guardrails software allows you to convert data into meaningful information, so you can quickly identify opportunities for clinical and operational improvement
  • With Guardrails CQI Reporter, you have the tools to spot subtle trends, measure the effectiveness of your IV formularies and best practices, and continuously optimize patient care

Alaris-Medley-Pump-Module-8100-version-7lClick here to download the PDF file.