Carefusion Alaris BD 8110 Features
The CareFusion Alaris 8110 Pump and Syringe modules are intended for facilities that utilize infusion and/or syringe pumps for the delivery of fluids, medications, blood, and blood products using continuous or intermittent delivery through clinically acceptable routes of administration; such as, intravenous (IV), intra-arterial (IA), subcutaneous, epidural, enteral, or irrigation of fluid spaces. The CareFusion 8110 Pump and Syringe modules are indicated for use on adults, pediatrics, and neonates. Up to four Pump and/or Syringe modules can be connected to the Alaris System.

The CareFusion 8110 syringe module is intended for facilities that use infusion for the delivery of fluids, medications, blood and blood products using continuous or intermittent delivery through clinically acceptable routes of administration (e.g. intravenous, intra-arterial or enteral).
The syringe module uses a unique pressure sensing disc which shortens the time to alarm, accurately monitors in line pressure, reduces delays upon infusion start up and decreases inadvertent bolus following occlusion release.

Carefusion Alaris BD 8110 Specifications

Bolus Volume, Maximum after Occlusion
Without Pressure Sensing Disc
Pressure Setting Low: 0.512 Bolus Volume (mL)
Pressure Setting Medium: 0.776 Bolus Volume (mL)
Pressure Setting High: 1.103 Bolus Volume (mL)
With Pressure Sensing Disc
Pressure Setting 300 mmHg: Back Off Disabled: 0.462; Back Off Enabled: 0.126 Pressure Setting 500 mmHg: Back Off Disabled: 0.575; Back Off Enabled: 0.331 Pressure Setting 1000 mmHg: Back Off Disabled: 0.839; Back Off Enabled: 0.323
Critical Volume
Maximum over-infusion which can occur in the event of a single-fault condition will not exceed 2% of nominal syringe fill volume during loading and 1% of maximum syringe travel after syringe loading.

Reviews

There are no reviews yet.

Be the first to review “Carefusion Alaris 8110 syringe pump module”

Alaris Infusion Pump Specifications

Dimensions

  • Height: 8.8 In (22.4 cm)
  • Width: 6.9 In (17.5 cm)
  • Depth: 9 In (22.9 cm)
  • Weight: 7.2 lb (3.2 kg)

Battery

  • Battery run time is a function of the number of modules attached and module activity. With a new, fully charged battery, the system operates as follows before a “BATTERY DISCHARGED” message occurs:
  • 6 Hours: with one Pump module infusing at 25 mL/h
  • 6 Hours: with one Pump module infusing at 25 mL/h and one Auto-ID module
  • 3 Hours: with four Pump modules infusing at 25 mL/h
  • 3 Hours: with four Pump modules infusing at 25 mL/h and one Auto-ID module
  • 4.5 Hours: with one active SpO2 module
  • 6 Hours: with one Syringe module or PCA module infusing at 5 mL/h
  • 3 Hours: with four Syringe modules, or one PCA module and three Syringe modules, infusing at 5 mL/h
  • 4 Hours: with one active EtCO2 module

Communication Data Port

  • RS-232 with an RJ45 connector

Memory

  • The System configuration/data set is stored in compact flash memory along with operating software.
  • The events and error logs are stored in the onboard flash memory in the Alaris PC unit and modules. This is a nonvolatile memory and can be held indefinitely or until replaced with new data and not lost when power is turned off or the battery is in a weak/discharged state.
  • Module-specific parameters are stored for 8 hours when the system is turned off. After 8 hours of continuous off-time, or if a module is detached, module-specific trend data (if applicable) and module-specific operating parameters are automatically purged. If a PCA, SpO2, or EtCO2 module is detached and replaced with another PCA, SpO2, or EtCO2 module, its module-specific trend data is purged.
  • Memory will not be lost due to a weak/discharged battery as data is stored on flash memory as noted.
  • Compact flash memory: Stores application software, audio wave files, DataSet, and hex files data for operating system software, all needed to operate the Alaris PC Unit System.
  • On-board flash memory: Contains software needed to initially turn on the Alaris 8105 System. Stores boot software applications, and events, errors, and battery logs.

IV Safety

  • Guardrails Suite MX software is the most comprehensive safety software available
  • The wirelessly enabled software is available on every device
  • Provides the right protection for every infusion by double-checking dose and duration, as well as delivery rate, protecting critical infusions like chemotherapy

Analytics

  • Guardrails software allows you to convert data into meaningful information, so you can quickly identify opportunities for clinical and operational improvement
  • With Guardrails CQI Reporter, you have the tools to spot subtle trends, measure the effectiveness of your IV formularies and best practices, and continuously optimize patient care

Alaris-Medley-Pump-Module-8100-version-7lClick here to download the PDF file.